Insulated Copper Tube
Single tube, pair tube, single coils, pair coils, and line sets for wholesale and OEM orders. Specify the copper tube, insulation, and finished length for each item.
Insulated Single Coils
Single-tube coils for orders that specify one copper tube size.
Insulated Pair Coils
Two insulated tube sizes supplied together for liquid and suction lines.
Copper Line Sets
Pre-insulated tubing ordered to the length and end connections your unit requires.
PVC-Coated Insulated Tubes
Insulated copper tubing with a PVC outer covering.
Insulated Copper-Aluminium Tubes
Copper-aluminium tubing options for compatible equipment.
Line Set Accessories
Browse the parts and accessories that go with your line set.
Find Your Insulated Copper Tube Size Guide
| Pair size (in.) | Tube 1 OD × wall (mm) | Tube 2 OD × wall (mm) | Insulation bores (mm) | HP reference | Supply length (m) |
|---|---|---|---|---|---|
| 1/4 × 3/8 | 6.35 × 0.80 | 9.52 × 0.80 | 8 ± 0.5 / 12 ± 0.5 | 1 | 1–50 |
| 1/4 × 1/2 | 6.35 × 0.80 | 12.70 × 0.80 | 8 ± 0.5 / 14 ± 0.5 | 1.5 | 1–50 |
| 1/4 × 5/8 | 6.35 × 0.80 | 15.88 × 1.00 | 8 ± 0.5 / 18 ± 0.5 | 2 | 1–50 |
| 3/8 × 5/8 | 9.52 × 0.80 | 15.88 × 1.00 | 12 ± 0.5 / 18 ± 0.5 | 3 | 1–50 |
| 3/8 × 3/4 | 9.52 × 0.80 | 19.05 × 1.00 | 12 ± 0.5 / 22 (+1.0) | 4 | 1–50 |
| 1/2 × 3/4 | 12.70 × 0.80 | 19.05 × 1.00 | 14 ± 0.5 / 22 ± 1.0 | 5 | 1–50 |
Show Single Coil & Line Set Sizes Hide Single Coil & Line Set Sizes
| Tube size (in.) | Tube OD (mm) | Tube wall (mm) | Insulation bore (mm) | Insulation thickness (mm) | Supply length (m) |
|---|---|---|---|---|---|
| 1/4 | 6.35 | 0.75 | 8 ± 0.5 | 8 | 1–50 |
| 3/8 | 9.52 | 0.80 | 12 ± 0.5 | 8 | 1–50 |
| 1/2 | 12.70 | 0.80 | 14 ± 0.5 | 8 | 1–50 |
| 5/8 | 15.88 | 1.00 | 18 ± 0.5 | 9 | 1–50 |
| 3/4 | 19.05 | 1.00 | 22 ± 1 | 9 | 1–50 |
| 7/8 | 22.22 | 1.20 | 25 ± 1 | 10 | 1–50 |
| 1 | 25.40 | 1.20 | 28 ± 1 | 10 | 1–50 |
| 1-1/8 | 28.58 | 1.20 | 32 ± 1 | 10 | 1–50 |
| 1-1/4 | 31.75 | 1.50 | 35 ± 1 | 10 | 1–50 |
| 1-1/2 | 38.10 | 1.50 | 42 ± 1 | 10 | 1–50 |
| Pair size (in.) | Tube 1 OD × wall (mm) | Tube 2 OD × wall (mm) | Insulation bores (mm) | HP reference | Supply length (m) |
|---|---|---|---|---|---|
| 1/4 × 3/8 | 6.35 × 0.80 | 9.52 × 0.80 | 8 ± 0.5 / 12 ± 0.5 | 1 | 1–50 |
| 1/4 × 1/2 | 6.35 × 0.80 | 12.70 × 0.80 | 8 ± 0.5 / 14 ± 0.5 | 1.5 | 1–50 |
| 1/4 × 5/8 | 6.35 × 0.80 | 15.88 × 1.00 | 8 ± 0.5 / 18 ± 0.5 | 2 | 1–50 |
| 3/8 × 5/8 | 9.52 × 0.80 | 15.88 × 1.00 | 12 ± 0.5 / 18 ± 0.5 | 3 | 1–50 |
| 3/8 × 3/4 | 9.52 × 0.80 | 19.05 × 1.00 | 12 ± 0.5 / 22 (+1.0) | 4 | 1–50 |
| 1/2 × 3/4 | 12.70 × 0.80 | 19.05 × 1.00 | 14 ± 0.5 / 22 ± 1.0 | 5 | 1–50 |
Show More Sizes & Accessories Hide More Sizes & Accessories
| Tube size (in.) | Tube OD (mm) | Tube wall (mm) | Insulation bore (mm) | Insulation thickness (mm) | Supply length (m) |
|---|---|---|---|---|---|
| 1/4 | 6.35 | 0.75 | 8 ± 0.5 | 8 | 1–50 |
| 3/8 | 9.52 | 0.80 | 12 ± 0.5 | 8 | 1–50 |
| 1/2 | 12.70 | 0.80 | 14 ± 0.5 | 8 | 1–50 |
| 5/8 | 15.88 | 1.00 | 18 ± 0.5 | 9 | 1–50 |
| 3/4 | 19.05 | 1.00 | 22 ± 1 | 9 | 1–50 |
| 7/8 | 22.22 | 1.20 | 25 ± 1 | 10 | 1–50 |
| 1 | 25.40 | 1.20 | 28 ± 1 | 10 | 1–50 |
| 1-1/8 | 28.58 | 1.20 | 32 ± 1 | 10 | 1–50 |
| 1-1/4 | 31.75 | 1.50 | 35 ± 1 | 10 | 1–50 |
| 1-1/2 | 38.10 | 1.50 | 42 ± 1 | 10 | 1–50 |
| Catalogue reference only. Confirm tube material, wall thickness and PVC covering thickness for the selected item. | |||||
| Tube size (in.) | Tube OD (mm) | Tube wall (mm) | Insulation bore (mm) | Insulation thickness (mm) | Supply length (m) |
|---|---|---|---|---|---|
| 1/4 | 6.35 | 0.75 | 8 ± 0.5 | 8 | 1–50 |
| 3/8 | 9.52 | 0.80 | 12 ± 0.5 | 8 | 1–50 |
| 1/2 | 12.70 | 0.80 | 14 ± 0.5 | 8 | 1–50 |
| 5/8 | 15.88 | 1.00 | 18 ± 0.5 | 9 | 1–50 |
| 3/4 | 19.05 | 1.00 | 22 ± 1 | 9 | 1–50 |
| 7/8 | 22.22 | 1.20 | 25 ± 1 | 10 | 1–50 |
| 1 | 25.40 | 1.20 | 28 ± 1 | 10 | 1–50 |
| 1-1/8 | 28.58 | 1.20 | 32 ± 1 | 10 | 1–50 |
| 1-1/4 | 31.75 | 1.50 | 35 ± 1 | 10 | 1–50 |
| 1-1/2 | 38.10 | 1.50 | 42 ± 1 | 10 | 1–50 |
| Tube size (in.) | Tube OD (mm) | Tube wall (mm) | Insulation bore (mm) | Insulation thickness (mm) | Supply length (m) |
|---|---|---|---|---|---|
| 1/4 | 6.35 | 0.75 | 8 ± 0.5 | 8 | 1–50 |
| 3/8 | 9.52 | 0.80 | 12 ± 0.5 | 8 | 1–50 |
| 1/2 | 12.70 | 0.80 | 14 ± 0.5 | 8 | 1–50 |
| 5/8 | 15.88 | 1.00 | 18 ± 0.5 | 9 | 1–50 |
| 3/4 | 19.05 | 1.00 | 22 ± 1 | 9 | 1–50 |
| 7/8 | 22.22 | 1.20 | 25 ± 1 | 10 | 1–50 |
| 1 | 25.40 | 1.20 | 28 ± 1 | 10 | 1–50 |
| 1-1/8 | 28.58 | 1.20 | 32 ± 1 | 10 | 1–50 |
| 1-1/4 | 31.75 | 1.50 | 35 ± 1 | 10 | 1–50 |
| 1-1/2 | 38.10 | 1.50 | 42 ± 1 | 10 | 1–50 |
| Pair name (in.) | Listed length |
|---|---|
| 1/2 + 1/4 | Specify on inquiry |
| 1/4 + 1/2 × 3 m | 3 m |
| 1/4 + 5/8 | Specify on inquiry |
| 3/8 + 5/8 | Specify on inquiry |
| Component | Sample kit quantity | Dimensions to specify |
|---|---|---|
| Refrigerant pipe | 2 | Tube OD, wall, finished length and ends |
| Drain hose | 1 | Hose diameter and length |
| Communication cable | 1 | Core count, conductor size and length |
| Wall sleeve | 1 | Sleeve diameter and length |
| Drainage joint | 1 | Connector type and mating diameter |
| Insulation foam | 1 | Bore, thickness and length |
| Sealing putty | 2 | Pack size |
| Wrapping tape | 2 | Width and roll length |
| Wall cover | 2 | Opening diameter and cover size |
Your Trusted Copper Tube Supplier
We supply copper tubes, copper coils, and fittings for HVAC, refrigeration, and industrial applications. Our product range covers insulated copper tubes, straight copper tubes, capillary tubes, and other copper tubing solutions.
We support bulk orders and customized specifications to meet different project and purchasing requirements.

Our Quality Inspection Process for Insulated Copper Pipes
Coil length
A tape is run alongside the unrolled coil to check its finished length.
Copper wall thickness
A digital gauge measures the copper wall at the exposed end of the tube.
Packed coil weight
The wrapped coil is weighed on a digital scale.
Packing label
The label identifies the product type, tube specification, coil length and roll quantity.
What to send for a quote
A size schedule is enough for standard orders. For a finished set, add the equipment drawing or the details of both tube ends.
- Tube format
- Single coil, pair coil or line set
- Copper dimensions
- OD and wall thickness for each tube
- Insulation
- Material, bore and jacket thickness
- Length and ends
- Length per roll or set, end fittings and any nuts required
- Order details
- Quantity by size, quantity unit, destination and label requirements
Insulated Copper Tube FAQs
What is insulated copper tube used for?
Insulated copper tube carries refrigerant between components in air conditioners, heat pumps and other HVAC systems. The insulation helps reduce heat gain or loss and limits condensation on cold lines. Pre-insulated tubing arrives with the insulation already fitted around the copper.
Is insulated copper tube sized by OD or ID?
HVAC refrigerant tubing is commonly specified by copper outside diameter (OD). For example, 1/2 in. corresponds to 12.70 mm copper OD in the size guide. List the copper wall thickness, insulation bore and insulation thickness separately. Measuring over the jacket gives the overall insulated diameter.
Which insulated copper tube sizes and coil lengths can I order?
The size guide lists single coils from 1/4 in. through 1-1/2 in. and pair sizes such as 1/4 × 3/8 in. and 1/4 × 1/2 in. The listed supply lengths run from 1–50 m for those coil ranges. Confirm the length and end configuration you need for each item.
How do single coils, pair coils and line sets differ?
A single coil gives you one tube size per roll. A pair coil gives you two sizes together for the liquid and suction lines. For a finished line set, specify both tube sizes, the cut length and the required end connections so it matches the equipment.
Can soft insulated copper tubing bend around corners?
Soft, annealed copper can be routed around bends. Ask for the minimum bend radius for your tube size and wall thickness, and check that the insulation can follow the bend without being crushed. A tight turn should be planned around the tubing and equipment requirements.
How do I choose the insulation thickness and jacket?
Start with the equipment requirements, then account for line temperature, ambient temperature and humidity. Specify the insulation material, bore and thickness in the order. For tubing exposed outdoors, also confirm the required weather or UV protection for the jacket.
Can the same insulated copper tube be used with R32 and R410A?
Check the installation manual for each equipment model. Confirm the tube material, outside diameter, minimum wall thickness, pressure requirements and connections. The refrigerant name alone does not identify a suitable tube or line set.
Do copper line sets include flare nuts and other accessories?
The included parts depend on the line-set configuration. Specify whether you need plain ends or flared ends with nuts, and list any additional items such as drain hose, wrapping tape or wall sleeves on the inquiry.
Can copper-aluminium tubing replace an all-copper line set?
Check whether the equipment manufacturer permits copper-aluminium tubing for that model before ordering. Compare the actual tube construction, dimensions, connections and application requirements. Matching outside diameters alone is insufficient to establish compatibility.
How much does insulated copper tube cost in bulk?
Pricing depends on tube material, outside diameter, wall thickness, insulation, cut length, fittings and order quantity. For a useful comparison, ask suppliers to quote the same specification and clearly state whether their price is per metre, per coil or per finished set.
Can I request custom sizes, lengths or private labels?
Send your target dimensions, insulation specification, finished length and quantity. For private labelling, include the artwork and tell us where it should appear, such as the jacket or carton. We can review these details together with the tubing specification.
What should I include in a wholesale insulated copper tube inquiry?
Include the product type, copper outside diameter and wall thickness for each tube, insulation bore and thickness, length per roll or set, end connections, quantity and destination. If the tubing is for a specific unit, attach the model number or a drawing.