Insulated Aluminium Tube

NEXNICE Insulated Aluminium Tube combines an aluminium tube with fitted insulation for air-conditioning pipework specified for aluminium. The range covers single-tube coils and paired tubing with end fittings, with catalogue tube sizes from 1/4 to 1-1/2 in. and supply lengths from 1 to 50 m.

Specify the tube dimensions, insulation, and end arrangement together. Custom outside diameters, wall thicknesses, and lengths are available on request; black rubber insulation is also listed as an option.

Single Coils and Paired Tubing

Single-Tube Coil

The single-coil format supplies one insulated tube size. It suits purchasing by individual pipe size, including orders where different diameters or lengths need to be stocked separately. The illustrated tube has an exposed metal end with a protective cap, leaving the connection arrangement to be specified for the intended assembly.

Paired Tubing with End Fittings

The paired format groups two insulated tubes for an equipment connection. The supplied photographs show nut-fitted ends and protective sleeves around the end sections. For this format, identify each tube separately: its outside diameter, wall thickness, insulation and length, followed by the required fitting details at each end.

A paired assembly is an ordering configuration, not a single tube size. The size table below lists individual tubes; it does not prescribe which two diameters must be paired.

Construction and Available Options

Aluminium Tube and Insulation Sized Separately

The metal tube is specified by outside diameter and wall thickness. The surrounding insulation has its own bore and thickness: the catalogue lists insulation thicknesses of 8, 9 and 10 mm across the range. Keeping these dimensions separate makes the purchase specification clear for both the fluid passage and the insulated assembly.

Fitted Insulation with a Textured Outer Surface

The illustrated product has white insulation with a textured outer surface. Supplying the tube already insulated removes the separate task of sleeving the main tube length. Connections and any site-cut sections still need insulation continuity appropriate to the installation.

Length, Insulation and End Preparation Options

Catalogue supply lengths are 1–50 m, with custom lengths accepted up to 50 m. Black rubber insulation can be requested. Nut-fitted ends are another listed option, allowing the end arrangement to be included in the order rather than assumed from a photograph.

Technical Specifications

The table lists individual aluminium tubes with their corresponding insulation dimensions. Dimensions are in millimetres unless stated otherwise.

Tube size (in.)Aluminium OD × wall (mm)Insulation ID (mm)Insulation thickness (mm)Supply length (m)
1/46.35 × 0.758 ± 0.581–50
3/89.52 × 0.812 ± 0.581–50
1/212.70 × 0.814 ± 0.581–50
5/815.88 × 1.018 ± 0.591–50
3/419.05 × 1.022 ± 191–50
7/822.22 × 1.225 ± 1101–50
125.40 × 1.228 ± 1101–50
1-1/828.58 × 1.232 ± 1101–50
1-1/431.75 × 1.535 ± 1101–50
1-1/238.10 × 1.542 ± 1101–50

OD means outside diameter; ID means inside diameter. The tolerances shown in the insulation column apply to the insulation bore, not to the aluminium tube OD. Custom tube dimensions are subject to the agreed order specification.

How to Select and Specify

Read the Tube Wall and Insulation Thickness Correctly

For the 5/8 in. entry, the aluminium tube is 15.88 mm OD with a 1.0 mm wall. Its insulation is listed as 18 ± 0.5 mm ID with a 9 mm thickness. These are two separate components: 9 mm is the insulation thickness, and 18 mm is not the refrigerant passage diameter.

Define Both Tubes in a Pair

Specify tube A and tube B independently, then add the common assembly length if both are the same. State whether the ends are plain, flared or supplied with the required nut arrangement, using the equipment drawing to define the mating connection. A nut appearance or cap colour does not identify its thread or sealing geometry.

Match the Material to the Equipment Requirement

An aluminium tube and a copper tube with the same nominal size are not automatically interchangeable. Where the project specifies paired copper tubing, review Insulated Copper Pair Coil as the relevant product family. Keep the required material, wall thickness and connection method together when comparing quotations.

Choose Length for the Route and Supply Format

Order the length needed for the planned route and the assembly allowance specified for the job. The 50 m catalogue maximum describes the available supply length; it does not mean every air conditioner permits a 50 m connecting line. For single coils intended for cutting into several pieces, state the coil length separately from the finished piece length.

🞪
× Filter
Product Categories
Preview for applied filters×
Loader
copper-y-type-elbow-angled-fitting-view (1) copper-y-type-elbow-three-fittings-group (1)
Copper Y-type Elbow
Copper Y-type Elbow
NEXNICE Copper Y-type Elbow connects three copper tube runs through a curved Y-shaped body. The catalogue offers inch sizes from 3/8 to 6-1/4 in. and a separate metric series from 10 to 159 mm. Select the three-port arrangement and body dimensions to match your assembly drawing.
insulated-aluminium-tube-coiled-tube-end-detail
Insulated Aluminium Tube
Insulated Aluminium Tube
NEXNICE Insulated Aluminium Tube combines an aluminium tube with fitted insulation for air-conditioning pipework specified for aluminium. The range covers single-tube coils and paired tubing with end fittings, with catalogue tube sizes from 1/4 to 1-1/2 in. and supply lengths from 1 to 50 m. Specify the tube dimensions, insulation, and end arrangement together. Custom outside diameters, wall thicknesses, and lengths are available on request; black rubber insulation is also listed as an option.
IGT (Inner Grooved Tube) copper pipe with diagonal bias-cut exposing internal micro-fin grooves for enhanced heat transfer and refrigerant turbulence optimization Three IGT (Inner Grooved Tube) copper pipes with beveled cut ends exposing dense micro-fin internal grooves designed for enhanced heat transfer, nucleate boiling enhancement, and maximum refrigerant turbulence in HVAC-R applications
Micro-fin Inner Grooved Copper Tube (IGT)
Micro-fin Inner Grooved Copper Tube (IGT)
Nexnice high-performance <span style="box-sizing: border-box;"><strong>inner grooved copper tubes</strong> use advanced <strong>micro-fin technology</strong> to maximize heat-exchange</span> efficiency in HVAC and refrigeration systems.
corrugated-copper-tube-open-end-detail-2000px
C12200 Spiral Corrugated Copper Tube for HVAC & Heat Exchangers
C12200 Spiral Corrugated Copper Tube for HVAC & Heat Exchangers
Spiral corrugated copper tubing for a defined heat-exchanger assembly. Specify the corrugation profile, tube dimensions, and connection ends on your drawing. <ul> <li>Spiral corrugated metal profile</li> <li>Pitch and depth to be specified</li> <li>Straight end details for assembly</li> </ul>
Insulated Copper Pair Coil with External Thread
Insulated Copper Pair Coil with External Thread
Insulated copper connecting tubing with a corrugated section visible near the end. Specify the required tube pair, corrugation position, and finished connection arrangement. • Corrugated metal section shown • Paired size schedule in the catalog • End profile and length to specify
1.6.3
Copper Fitting Refrigeration Cross-Over Coupling C×C
Copper Fitting Refrigeration Cross-Over Coupling C×C
2.1.18

Get in Touch

Our Location

D4-109,Liangzhu Culture Park,Haishu District,315175 Ningbo,CHINA

Call Us On

+ 86 137 5740 9608

Email us

sales@zengo.com.cn

Whether you have any questions about our products, please feel free to contact us, we will reply as soon as possible.

News from NEXNICE

Two white-insulated copper tube ends with brass flare nuts on a white background with the NEXNICE logo, AI-edited product image.

Flared vs Quick-Connect Mini Split Line Sets: Installation and Compatibility

Mini split line set installation begins by identifying the connection system the equipment accepts. Conventional flared tubing and a factory-charged quick-connect assembly can look similar....

Water droplets on copper exposed between two black insulation sleeves against a white background, AI illustration with the NEXNICE logo.

Mini Split Line Set Condensation: Causes and How to Troubleshoot

Water dripping near a mini split line set does not identify the source of the water. It may be condensation forming on a cold surface,....

Copper tube samples surrounded by white and black foam insulation on a white background, AI-generated material illustration with the NEXNICE logo.

PE vs Rubber Insulation for Mini Split Line Sets: Which Should You Choose?

Choose mini split line set insulation by the conditions it must withstand: pipe temperature, local humidity, outdoor exposure, and the way the finished assembly will....