Insulated Copper Pair Coil with External Thread

Insulated copper connecting tubing with a corrugated section visible near the end. Specify the required tube pair, corrugation position, and finished connection arrangement.
• Corrugated metal section shown
• Paired size schedule in the catalog
• End profile and length to specify

Product Overview

Nexnice’s catalog presents this configuration as Insulated Copper Tube 4 Side Wave. The product illustration shows a corrugated copper section alongside the insulation and a smooth end section with a nut.

The location and shape of the corrugation are part of the product specification. A drawing should identify the corrugated section, smooth connection ends, and insulation coverage so the requested assembly can be distinguished from fully corrugated tubing.

Product Features and Options

Defined Corrugated Section

The illustration distinguishes a shaped copper section from the surrounding insulation. Specify its position, length, and required profile directly. The term “wave” should not be used as a substitute for those dimensions.

Paired Tube Schedule

The related catalog table lists six pair combinations and the wall thickness of each tube. The two tube sizes should be selected from the equipment requirements, with the profile checked for the intended assembly.

Insulation and End Details

Black rubber insulation and nut-fitted ends are listed as options in the catalog notes. Include insulation thickness, exposed-end lengths, and connection details with the profile drawing to define the finished product.

Technical Specifications

Tube size OD × wall (mm) HP Insulation ID (mm) Length
1/4×3/8 6.35×0.80 / 9.52×0.80 1 HP Φ8 (±0.5) / Φ12 (±0.5) 1~25M
1/4×1/2 6.35×0.80 / 12.7×0.80 1.5 HP Φ8 (±0.5) / Φ14 (±0.5) 1~25M
1/4×5/8 6.35×0.80 / 15.88×1.0 2HP Φ8 (±0.5) / Φ18 (±0.5) 1~25M
3/8×5/8 9.52×0.80 / 15.88×1.0 3HP Φ12 (±0.5) / Φ18 (±0.5) 1~25M
3/8×3/4 9.52×0.80 / 19.05×1.0 4HP Φ12 (±0.5) / Φ22 (+1.0) 1~25M
1/2×3/4 12.7×0.80 / 19.05×1.0 5HP Φ14 (±0.5) / Φ22 (±1.0) 1~25M

Application and Selection

Use this configuration where the approved assembly drawing calls for the illustrated corrugated section. Confirm the intended function and geometry before substituting it for an ordinary smooth connecting tube.

The variant table lists supply lengths of 1–25 meters, while a separate note mentions custom lengths up to 50 meters. The actual length available for the selected profile needs written confirmation.

Ordering Information

To request a quotation, please provide:

  • Both tube sizes and wall thicknesses.
  • Corrugation drawing with location, pitch, depth, and length.
  • Finished assembly length and exposed-end dimensions.
  • Insulation material and thickness.
  • Nut or other end-connection requirements and quantity.

Related product: Insulated Copper Single Coil

Reviews

There are no reviews yet.

Be the first to review “Insulated Copper Pair Coil with External Thread”

Your email address will not be published. Required fields are marked *

🞪
× Filter
Product Categories
Preview for applied filters×
Loader
IGT (Inner Grooved Tube) copper pipe with diagonal bias-cut exposing internal micro-fin grooves for enhanced heat transfer and refrigerant turbulence optimization Three IGT (Inner Grooved Tube) copper pipes with beveled cut ends exposing dense micro-fin internal grooves designed for enhanced heat transfer, nucleate boiling enhancement, and maximum refrigerant turbulence in HVAC-R applications
Micro-fin Inner Grooved Copper Tube (IGT)
Micro-fin Inner Grooved Copper Tube (IGT)
Nexnice high-performance <span style="box-sizing: border-box;"><strong>inner grooved copper tubes</strong> use advanced <strong>micro-fin technology</strong> to maximize heat-exchange</span> efficiency in HVAC and refrigeration systems.
Nexnice copper tubes specifically designed as inner tubes for coaxial and tube-in-tube heat exchangers. Flexible spiral corrugated copper pipe showing bending capability for HVAC and refrigeration units.
C12200 Spiral Corrugated Copper Tube for HVAC & Heat Exchangers
C12200 Spiral Corrugated Copper Tube for HVAC & Heat Exchangers
Spiral corrugated copper tubing for a defined heat-exchanger assembly. Specify the corrugation profile, tube dimensions, and connection ends on your drawing. <ul> <li>Spiral corrugated metal profile</li> <li>Pitch and depth to be specified</li> <li>Straight end details for assembly</li> </ul>
Insulated Copper Pair Coil with External Thread
Insulated Copper Pair Coil with External Thread
Insulated copper connecting tubing with a corrugated section visible near the end. Specify the required tube pair, corrugation position, and finished connection arrangement. • Corrugated metal section shown • Paired size schedule in the catalog • End profile and length to specify
1.6.3
Copper Fitting Refrigeration Cross-Over Coupling C×C
Copper Fitting Refrigeration Cross-Over Coupling C×C
2.1.18
Copper Fitting Refrigeration P-Trap C×C
Copper Fitting Refrigeration P-Trap C×C
A formed copper P-trap with two cup connections for refrigeration layouts that specify this trap geometry. Match the trap dimensions and end orientation to the system drawing. <ul> <li>P-trap body geometry</li> <li>Two cup connections</li> <li>Depth and orientation specified by design</li> </ul>
2.1.17
Nexnice Copper Fitting Refrigeration P-Trap C×C with two visible copper openings on a white background Nexnice Copper Fitting Refrigeration P-Trap C×C with two visible copper openings on a white background
Copper Fitting Refrigeration Return Bend C×C
Copper Fitting Refrigeration Return Bend C×C
A copper return bend for a 180-degree change in tube direction. Two cup ends connect parallel tube sections within the required assembly spacing. <ul> <li>180-degree return geometry</li> <li>C × C connections</li> <li>Center spacing controls assembly fit</li> </ul>
2.1.16

Get in Touch

Our Location

D4-109,Liangzhu Culture Park,Haishu District,315175 Ningbo,CHINA

Call Us On

+ 86 137 5740 9608

Email us

sales@zengo.com.cn

Whether you have any questions about our products, please feel free to contact us, we will reply as soon as possible.

News from NEXNICE

Concentric, oval and eccentric tube cross-sections with diameter and center-offset markings on a white background, technical diagram.

Small-Diameter Copper Capillary Tube: Geometry, Inspection and Quality Control

A capillary tube can pass an outside-diameter check and still leave important questions unanswered. Is the bore the intended shape? Is the wall concentric? Did....

Copper Capillary Tubes for Refrigeration: From a Starting Size to a Validated System

A refrigeration capillary can work satisfactorily at one test point and still leave unanswered questions about a hot room, a warm product load or a....

Copper capillary tubing coil on a clean white background.

Copper Capillary Tube Size Chart: Read ID, OD and Units Without Guesswork

A number like 0.031 isn’t a usable tube specification until you know what it means and what units it uses. It could be an inside....

Online Contact