Copper Y-type Elbow

NEXNICE Copper Y-type Elbow connects three copper tube runs through a curved Y-shaped body. The catalogue offers inch sizes from 3/8 to 6-1/4 in. and a separate metric series from 10 to 159 mm. Select the three-port arrangement and body dimensions to match your assembly drawing.

Copper Y-type Elbow for Three-Port Tube Junctions

NEXNICE Copper Y-type Elbow brings three tube connections into a curved Y-shaped junction. Part of the Copper Welding Series, it provides a branch-fitting option for copper pipework whose assembly drawing calls for this layout. The catalogue lists inch sizes from 3/8 to 6-1/4 in. and a separate metric series from 10 to 159 mm.

A Branch Connection with Curved Arms

The fitting has one stem and two curved arms, each ending in a tube connection. This gives the pipework a three-way junction at the specified position in the assembly. For an equipment maker, the useful distinction is the branch layout: the component must align with three adjoining tube runs, including their spacing and direction.

Use the product name to identify the fitting family, then use a dimensioned drawing to identify the part. A catalogue size alone does not define the three-port arrangement or the overall space occupied by the curved body.

Construction and Connection Features

Three Connection Points in One Fitting

The common junction and two branch arms are contained in one fitting body. In the bill of materials, specify this as a Y-type copper fitting and identify each connection separately. This keeps the branch component distinct from the straight tubes and other bends used around it.

Curved Arms Define the Tube Approach

The illustrated arms curve away from the junction before reaching the end openings. Their shape makes branch-end spacing and straight-end length relevant to fit, especially when the adjoining tubes are held in a fixed fixture. Allow access around all three joints as well as clearance for the body itself.

Socket-Style Tube Ends

The supplied close-up shows open, expanded tube ends. For the joint detail, match the receiving end to the mating tube OD and specify insertion depth and the required joining procedure on the assembly drawing. Keep the tube-fit dimensions separate from the outside dimensions of the socket mouth.

Catalogue Size Range

The catalogue presents two size series. The inch entries below retain the millimetre references printed in parentheses in the source; those references include rounded values and are not manufacturing tolerances. The separate metric table lists the metric options in their original order.

Inch Size Series

Catalogue size (in.)Catalogue reference (mm)
3/89.52
1/212.7
5/815.88
3/419.05
7/822.23
125.4
1-1/828.6
1-1/432
1-3/835
1-1/238
1-5/842
1-3/445
2-1/854
2-5/867
376
4-1/4108
5-1/4133
6-1/4159

Metric Size Series

Catalogue metric size (mm)
10
12
15
16
22
25
28
32
35
38
42
45
54
67
76
108
133
159

These are independent size lists, not a row-by-row conversion chart. The size designation should be read together with the approved connection drawing for the ordered fitting.

How to Specify the Correct Fitting

Identify All Three Ports

Label the stem A and the two arms B and C on a sketch. For each port, state the mating tube OD, the inch or metric size system, and the receiving-end dimensions required by the joint design. Do not use a single size entry as a substitute for an A × B × C connection schedule.

Check Fit Using Dimensions, Not Table Position

For example, the inch list shows 3/4 in. with a 19.05 mm reference, while the metric series includes 16 mm. These are different size entries, even though they appear on the same row in the original catalogue. Use the mating tube specification to select the appropriate series.

Include the Dimensions That Locate the Tubes

Add branch-end spacing, end-axis directions, straight-end lengths and insertion depths to the drawing. Also show the available installation envelope. Two fittings described by the same tube size can still occupy different positions in a fixed assembly if these dimensions differ.

Choose a Branch or a Return According to the Route

A route that joins three tubes calls for a branch fitting. If the drawing instead connects two parallel tube sections through a 180-degree return, review the Copper Return Bend C × C and its centre spacing. The number of connections and the required tube route determine which fitting family to specify.

🞪
× Filter
Product Categories
Preview for applied filters×
Loader
copper-y-type-elbow-angled-fitting-view (1) copper-y-type-elbow-three-fittings-group (1)
Copper Y-type Elbow
Copper Y-type Elbow
NEXNICE Copper Y-type Elbow connects three copper tube runs through a curved Y-shaped body. The catalogue offers inch sizes from 3/8 to 6-1/4 in. and a separate metric series from 10 to 159 mm. Select the three-port arrangement and body dimensions to match your assembly drawing.
insulated-aluminium-tube-coiled-tube-end-detail
Insulated Aluminium Tube
Insulated Aluminium Tube
NEXNICE Insulated Aluminium Tube combines an aluminium tube with fitted insulation for air-conditioning pipework specified for aluminium. The range covers single-tube coils and paired tubing with end fittings, with catalogue tube sizes from 1/4 to 1-1/2 in. and supply lengths from 1 to 50 m. Specify the tube dimensions, insulation, and end arrangement together. Custom outside diameters, wall thicknesses, and lengths are available on request; black rubber insulation is also listed as an option.
IGT (Inner Grooved Tube) copper pipe with diagonal bias-cut exposing internal micro-fin grooves for enhanced heat transfer and refrigerant turbulence optimization Three IGT (Inner Grooved Tube) copper pipes with beveled cut ends exposing dense micro-fin internal grooves designed for enhanced heat transfer, nucleate boiling enhancement, and maximum refrigerant turbulence in HVAC-R applications
Micro-fin Inner Grooved Copper Tube (IGT)
Micro-fin Inner Grooved Copper Tube (IGT)
Nexnice high-performance <span style="box-sizing: border-box;"><strong>inner grooved copper tubes</strong> use advanced <strong>micro-fin technology</strong> to maximize heat-exchange</span> efficiency in HVAC and refrigeration systems.
corrugated-copper-tube-open-end-detail-2000px
C12200 Spiral Corrugated Copper Tube for HVAC & Heat Exchangers
C12200 Spiral Corrugated Copper Tube for HVAC & Heat Exchangers
Spiral corrugated copper tubing for a defined heat-exchanger assembly. Specify the corrugation profile, tube dimensions, and connection ends on your drawing. <ul> <li>Spiral corrugated metal profile</li> <li>Pitch and depth to be specified</li> <li>Straight end details for assembly</li> </ul>
Insulated Copper Pair Coil with External Thread
Insulated Copper Pair Coil with External Thread
Insulated copper connecting tubing with a corrugated section visible near the end. Specify the required tube pair, corrugation position, and finished connection arrangement. • Corrugated metal section shown • Paired size schedule in the catalog • End profile and length to specify
1.6.3
Copper Fitting Refrigeration Cross-Over Coupling C×C
Copper Fitting Refrigeration Cross-Over Coupling C×C
2.1.18

Get in Touch

Our Location

D4-109,Liangzhu Culture Park,Haishu District,315175 Ningbo,CHINA

Call Us On

+ 86 137 5740 9608

Email us

sales@zengo.com.cn

Whether you have any questions about our products, please feel free to contact us, we will reply as soon as possible.

News from NEXNICE

Two white-insulated copper tube ends with brass flare nuts on a white background with the NEXNICE logo, AI-edited product image.

Flared vs Quick-Connect Mini Split Line Sets: Installation and Compatibility

Mini split line set installation begins by identifying the connection system the equipment accepts. Conventional flared tubing and a factory-charged quick-connect assembly can look similar....

Water droplets on copper exposed between two black insulation sleeves against a white background, AI illustration with the NEXNICE logo.

Mini Split Line Set Condensation: Causes and How to Troubleshoot

Water dripping near a mini split line set does not identify the source of the water. It may be condensation forming on a cold surface,....

Copper tube samples surrounded by white and black foam insulation on a white background, AI-generated material illustration with the NEXNICE logo.

PE vs Rubber Insulation for Mini Split Line Sets: Which Should You Choose?

Choose mini split line set insulation by the conditions it must withstand: pipe temperature, local humidity, outdoor exposure, and the way the finished assembly will....

Online Contact

Get A Quote