C12200 Spiral Corrugated Copper Tube for HVAC & Heat Exchangers

Spiral corrugated copper tubing for a defined heat-exchanger assembly. Specify the corrugation profile, tube dimensions, and connection ends on your drawing.

  • Spiral corrugated metal profile
  • Pitch and depth to be specified
  • Straight end details for assembly

Product Overview

The Nexnice spiral corrugated copper tube features a shaped metal profile along the tube body. The crest diameter, corrugation pitch, and depth distinguish the required geometry from a smooth tube of similar overall size.

A product drawing is the basis for this inquiry. It should show the profiled section and any straight ends separately, including the measurements needed to fit the tube inside or alongside the mating components.

Product Features and Options

Corrugation Geometry

Specify the profile using a section drawing and longitudinal dimensions. State which surface serves as the diameter reference so you can consistently check the maximum outer envelope and intended clearance.

Connection Ends

Straight end length and diameter influence how the tube joins the assembly. Identify the end shape, cut position, and any additional preparation independently from the corrugated body.

Assembly-Based Review

Include the mating-tube dimensions or assembly sketch when the tube forms part of a coaxial or tube-in-tube design. The requested profile must be evaluated with the surrounding parts and operating requirements.

Spiral Corrugated Copper Tube

Technical Specifications

Specification Standard Range
Outer Diameter (OD) 1/4″, 5/16″, 3/8″ (Customizable up to 1″)
Wall Thickness 0.35 mm – 1.2 mm
Max Coil Length Up to 50 Meters
Insulation Options Black Rubber (NBR/EPDM) with customizable film color
Profile requirement Details for review
Metal section Material, diameter reference, and wall
Corrugation Pitch, depth, and section length
Ends Straight length, diameter, and preparation
Assembly Mating dimensions and operating requirements

Send the required dimensions and operating conditions for review with the selected profile.

Application and Selection

Select corrugated tubing from an approved design that calls for this profile. A corrugated outside shape and an internal micro-fin profile are different features; one specification should not be substituted for the other.

Provide the intended fluid, pressure, and temperature requirements for technical review. A product photograph does not establish a pressure rating, corrosion allowance, or guaranteed heat-transfer improvement.

Ordering Information

To request a quotation, please provide:

  • Material requirement and profile drawing.
  • Diameter reference, wall thickness, corrugation pitch, and depth.
  • Length of the profiled section and straight ends.
  • Mating-part dimensions and connection requirements.
  • Quantity, application conditions, and required test documents.

Related product: Micro-Fin Inner-Grooved Copper Tube

🞪
× Filter
Product Categories
Preview for applied filters×
Loader
IGT (Inner Grooved Tube) copper pipe with diagonal bias-cut exposing internal micro-fin grooves for enhanced heat transfer and refrigerant turbulence optimization Three IGT (Inner Grooved Tube) copper pipes with beveled cut ends exposing dense micro-fin internal grooves designed for enhanced heat transfer, nucleate boiling enhancement, and maximum refrigerant turbulence in HVAC-R applications
Micro-fin Inner Grooved Copper Tube (IGT)
Micro-fin Inner Grooved Copper Tube (IGT)
Nexnice high-performance <span style="box-sizing: border-box;"><strong>inner grooved copper tubes</strong> use advanced <strong>micro-fin technology</strong> to maximize heat-exchange</span> efficiency in HVAC and refrigeration systems.
Nexnice copper tubes specifically designed as inner tubes for coaxial and tube-in-tube heat exchangers. Flexible spiral corrugated copper pipe showing bending capability for HVAC and refrigeration units.
C12200 Spiral Corrugated Copper Tube for HVAC & Heat Exchangers
C12200 Spiral Corrugated Copper Tube for HVAC & Heat Exchangers
Spiral corrugated copper tubing for a defined heat-exchanger assembly. Specify the corrugation profile, tube dimensions, and connection ends on your drawing. <ul> <li>Spiral corrugated metal profile</li> <li>Pitch and depth to be specified</li> <li>Straight end details for assembly</li> </ul>
Insulated Copper Pair Coil with External Thread
Insulated Copper Pair Coil with External Thread
Insulated copper connecting tubing with a corrugated section visible near the end. Specify the required tube pair, corrugation position, and finished connection arrangement. • Corrugated metal section shown • Paired size schedule in the catalog • End profile and length to specify
1.6.3
Copper Fitting Refrigeration Cross-Over Coupling C×C
Copper Fitting Refrigeration Cross-Over Coupling C×C
2.1.18
Copper Fitting Refrigeration P-Trap C×C
Copper Fitting Refrigeration P-Trap C×C
A formed copper P-trap with two cup connections for refrigeration layouts that specify this trap geometry. Match the trap dimensions and end orientation to the system drawing. <ul> <li>P-trap body geometry</li> <li>Two cup connections</li> <li>Depth and orientation specified by design</li> </ul>
2.1.17
Nexnice Copper Fitting Refrigeration P-Trap C×C with two visible copper openings on a white background Nexnice Copper Fitting Refrigeration P-Trap C×C with two visible copper openings on a white background
Copper Fitting Refrigeration Return Bend C×C
Copper Fitting Refrigeration Return Bend C×C
A copper return bend for a 180-degree change in tube direction. Two cup ends connect parallel tube sections within the required assembly spacing. <ul> <li>180-degree return geometry</li> <li>C × C connections</li> <li>Center spacing controls assembly fit</li> </ul>
2.1.16

Get in Touch

Our Location

D4-109,Liangzhu Culture Park,Haishu District,315175 Ningbo,CHINA

Call Us On

+ 86 137 5740 9608

Email us

sales@zengo.com.cn

Whether you have any questions about our products, please feel free to contact us, we will reply as soon as possible.

News from NEXNICE

Concentric, oval and eccentric tube cross-sections with diameter and center-offset markings on a white background, technical diagram.

Small-Diameter Copper Capillary Tube: Geometry, Inspection and Quality Control

A capillary tube can pass an outside-diameter check and still leave important questions unanswered. Is the bore the intended shape? Is the wall concentric? Did....

Copper Capillary Tubes for Refrigeration: From a Starting Size to a Validated System

A refrigeration capillary can work satisfactorily at one test point and still leave unanswered questions about a hot room, a warm product load or a....

Copper capillary tubing coil on a clean white background.

Copper Capillary Tube Size Chart: Read ID, OD and Units Without Guesswork

A number like 0.031 isn’t a usable tube specification until you know what it means and what units it uses. It could be an inside....

Online Contact

Get A Quote