Insulated Copper Single Coil

Nexnice insulated copper single coil is one factory-insulated tube per coil for split and centralized air-conditioning runs. Soft-annealed cathode copper, cleaned and capped, in three-layer PE (black rubber on request). Catalog sizes run from 1/4 (6.35×0.75) through 1 1/2, with a length of 1~50 m. For a wholesale quote, send the company name, tube type (single coil), OD × wall, insulation jacket, cut length, and quantity.

• One insulated tube per coil
• Catalog OD: 6.35–38.10 mm
• Lengths listed from 1 to 50 m

Product Overview

Nexnice insulated copper single coils provide one tube size in a coiled, pre-insulated format. This gives buyers a separate specification for each line when tube sizes or required lengths differ across an installation.

The copper tube and its insulation have different dimensions. Copper outside diameter determines the metal tube size; insulation bore and thickness determine the covering. Keeping those measurements separate helps avoid ordering an insulation dimension as a copper dimension.

Product Features and Options

Individual Line Specification

Order each tube size and coil length separately. The single-coil format is useful when a project schedule calls for different lengths on different lines or when only one tube size is required for the intended assembly.

Tube and Insulation Options

The catalog shows a layered polyethylene insulation construction and offers black rubber as an alternative. Specify the covering required for the selected copper tube, including insulation thickness and any project documentation requirements.

Catalog and Custom Dimensions

Ten tube sizes are listed, with individual wall thicknesses and 1–50 meter supply lengths. Custom outside diameters, wall thicknesses, and lengths may be requested; the finished specification should identify all three together.

Insulated Copper Single Coil

Technical Specifications

Size in Tube OD mm Tube wall mm
1/4 6.35 0.75
3/8 9.52 0.80
1/2 12.70 0.80
5/8 15.88 1.00
3/4 19.05 1.00
7/8 22.22 1.20
1 25.40 1.20
1-1/8 28.58 1.20
1-1/4 31.75 1.50
1-1/2 38.10 1.50

Catalog supply length: 1–50 m. Outside diameter excludes insulation.

Application and Selection

Select the single coil from the equipment’s tube schedule. Check the copper wall and insulation dimensions as well as the diameter, especially where more than one product format uses the same nominal tube size.

If two single coils will serve one air-conditioning connection, specify both lines independently. Pairing two products for an installation does not change the dimensional information required for each tube.

Ordering Information

To request a quotation, please provide:

  • Copper OD and wall thickness.
  • Coil length and quantity by tube size.
  • Insulation material, bore, and thickness.
  • End treatment and nuts if required.
  • Equipment specifications and required documentation.

Related product: Insulated Copper Pair Coil

Reviews

There are no reviews yet.

Be the first to review “Insulated Copper Single Coil”

Your email address will not be published. Required fields are marked *

🞪
× Filter
Product Categories
Preview for applied filters×
Loader
IGT (Inner Grooved Tube) copper pipe with diagonal bias-cut exposing internal micro-fin grooves for enhanced heat transfer and refrigerant turbulence optimization Three IGT (Inner Grooved Tube) copper pipes with beveled cut ends exposing dense micro-fin internal grooves designed for enhanced heat transfer, nucleate boiling enhancement, and maximum refrigerant turbulence in HVAC-R applications
Micro-fin Inner Grooved Copper Tube (IGT)
Micro-fin Inner Grooved Copper Tube (IGT)
Nexnice high-performance <span style="box-sizing: border-box;"><strong>inner grooved copper tubes</strong> use advanced <strong>micro-fin technology</strong> to maximize heat-exchange</span> efficiency in HVAC and refrigeration systems.
Nexnice copper tubes specifically designed as inner tubes for coaxial and tube-in-tube heat exchangers. Flexible spiral corrugated copper pipe showing bending capability for HVAC and refrigeration units.
C12200 Spiral Corrugated Copper Tube for HVAC & Heat Exchangers
C12200 Spiral Corrugated Copper Tube for HVAC & Heat Exchangers
Spiral corrugated copper tubing for a defined heat-exchanger assembly. Specify the corrugation profile, tube dimensions, and connection ends on your drawing. <ul> <li>Spiral corrugated metal profile</li> <li>Pitch and depth to be specified</li> <li>Straight end details for assembly</li> </ul>
Insulated Copper Pair Coil with External Thread
Insulated Copper Pair Coil with External Thread
Insulated copper connecting tubing with a corrugated section visible near the end. Specify the required tube pair, corrugation position, and finished connection arrangement. • Corrugated metal section shown • Paired size schedule in the catalog • End profile and length to specify
1.6.3
Copper Fitting Refrigeration Cross-Over Coupling C×C
Copper Fitting Refrigeration Cross-Over Coupling C×C
2.1.18
Copper Fitting Refrigeration P-Trap C×C
Copper Fitting Refrigeration P-Trap C×C
A formed copper P-trap with two cup connections for refrigeration layouts that specify this trap geometry. Match the trap dimensions and end orientation to the system drawing. <ul> <li>P-trap body geometry</li> <li>Two cup connections</li> <li>Depth and orientation specified by design</li> </ul>
2.1.17
Nexnice Copper Fitting Refrigeration P-Trap C×C with two visible copper openings on a white background Nexnice Copper Fitting Refrigeration P-Trap C×C with two visible copper openings on a white background
Copper Fitting Refrigeration Return Bend C×C
Copper Fitting Refrigeration Return Bend C×C
A copper return bend for a 180-degree change in tube direction. Two cup ends connect parallel tube sections within the required assembly spacing. <ul> <li>180-degree return geometry</li> <li>C × C connections</li> <li>Center spacing controls assembly fit</li> </ul>
2.1.16

Get in Touch

Our Location

D4-109,Liangzhu Culture Park,Haishu District,315175 Ningbo,CHINA

Call Us On

+ 86 137 5740 9608

Email us

sales@zengo.com.cn

Whether you have any questions about our products, please feel free to contact us, we will reply as soon as possible.

News from NEXNICE

Concentric, oval and eccentric tube cross-sections with diameter and center-offset markings on a white background, technical diagram.

Small-Diameter Copper Capillary Tube: Geometry, Inspection and Quality Control

A capillary tube can pass an outside-diameter check and still leave important questions unanswered. Is the bore the intended shape? Is the wall concentric? Did....

Copper Capillary Tubes for Refrigeration: From a Starting Size to a Validated System

A refrigeration capillary can work satisfactorily at one test point and still leave unanswered questions about a hot room, a warm product load or a....

Copper capillary tubing coil on a clean white background.

Copper Capillary Tube Size Chart: Read ID, OD and Units Without Guesswork

A number like 0.031 isn’t a usable tube specification until you know what it means and what units it uses. It could be an inside....

Online Contact

Get A Quote